Instruments for dental professionals, clean and sterilize before use max. 180°C/356°F.
Mini McCall with with ErgoSense® Handle (sharpen-free) 222-223MSDES
- For deep, narrow pockets
- Sharper, slightly rounded tip (not sickle-shaped)
LM23 Slim Sickle Scaler with ErgoSense® Handle (sharpen-free) 343-344SDES
- A thinner version of the traditional and popular LM23 scaler
- Enables efficient and pleasant anterior and posterior instrumentation
- The thinner blade design allows for even better access to interproximal areas.
- Ideal angles and slightly extended lower shank provide convenient access to all posterior and anterior surfaces.
NV1 Sickle Scaler with ErgoSense® Handle (sharpen-free) 317-318SDES
- For efficient and pleasant supragingival calculus removal from anterior surfaces and interproximal areas.
- NV1 SD sickle scaler has two different types of working ends enabling efficient anterior instrumentation:
- the sickle end, with two cutting edges, is excellent for removing interproximal calculus and stain,
- the disc end is effective for calculus and stain removal from lingual surfaces of incisors.
NV2 Sickle Scaler with ErgoSense® Handle (sharpen-free) 319-320SDES
- For efficient and pleasant supragingival calculus removal from posterior surfaces and interproximal areas.
- NV2 SD posterior sickle scaler aids ergonomic calculus removal from all posterior supragingival areas.
- The heavily angled, long shank allow great posterior access, and the thin and long blades provide easy access to interproximals.
LM23 Sickle Scaler with ErgoSense® Handle (sharpen-free) 313-314SDES
- Posterior scaler
- Shorter blade and longer lower shank than in the Mini Sickle (311-312)
Mini Sickle Scaler with ErgoSense® Handle (sharpen-free) 311-312SDES
- For all tooth surfaces, especially proximal surfaces
- Fine, slightly angled blade
204S Sickle Scaler with ErgoSense® Handle (sharpen-free) 303-304SDES
- Sharply angulated shank and very fine working end
Micro Sickle Scaler with ErgoSense® Handle (sharpen-free) 301-302SDES
- Anterior/posterior scaler
- Delicate working end, elongated shank
- Especially for tight interdental spaces
Standard Syntette™ Anterior Dual Gracey Curette with ErgoSense® Handle (sharpen-free) 275-276SDES
- LM Dual Gracey™ curette, a combination of universal curette Gracey 1/2 and Gracey 7/8
- For removal of supra and subgingival calculus in anterior and premolar areas
- For all tooth surfaces
Mini Syntette™ Anterior Dual Gracey Curette with ErgoSense® Handle (sharpen-free) 275-276MSDES
- LM Dual Gracey™ curette, a combination of universal curette Mini Gracey 1/2 and Mini Gracey 7/8
- For removal of supra and subgingival calculus in anterior and premolar areas
- For all tooth surfaces
- Mini model is excellent in narrow and deep pockets
Standard Gracey 17/18 Curette with ErgoSense® Handle (sharpen-free) 247-248SDES
- Area specific curette for the removal of deep subgingival calculus
- For molars’ distal surfaces
- Blade shank more sharply angulated than in Gracey 13/14 (213-214) for better access
Mini Gracey 17/18 Curette with ErgoSense® Handle (sharpen-free) 247-248MSDES
- Area specific curette for the removal of deep subgingival calculus
- For molars’ distal surfaces
- Blade shank more sharply angulated than in Mini Gracey 13/14 for better access
Standard Gracey 15/16 Curette with ErgoSense® Handle (sharpen-free) 245-246SDES
- Area specific curettes for the removal of deep subgingival calculus
- For molars’ mesial surfaces
- Blade shank more sharply angulated than in Gracey 11/12 for better access
Mini Gracey 15/16 Curette with ErgoSense® Handle (sharpen-free) 245-246MSDES
- Area specific curette for the removal of deep subgingival calculus
- For molars’ mesial surfaces
- Blade shank more sharply angulated than in Mini Gracey 11/12 for better access
Barnhart 5/6 Curette with ErgoSense® Handle (sharpen-free) 227-228SDES
- Universal curette designed for the removal of moderate to heavy calculus from all supra- and subgingival tooth surfaces
- For molars
- Shorter lower shank
Columbia 4L/4R Curette with ErgoSense® Handle (sharpen-free) 219-220SDES
- For incisors, canines and premolars
- For heavier calculus
Syntette™ Standard Dual Gracey with ErgoSense® Handle (sharpen-free) 215-216SDES
- The original LM Dual Gracey™ curette, a combination of universal curette Mini Gracey 11/12 and Mini Gracey 13/14
- For removal of supra and subgingival calculus in premolar and molar areas
- For all tooth surfaces
Mini Syntette™ Dual Gracey Curette with ErgoSense® Handle (sharpen-free) 215-216MSDES
- The original LM Dual Gracey™ curette, a combination of universal curette Mini Gracey 11/12 and Mini Gracey 13/14
- For removal of supra and subgingival calculus in premolar and molar areas
- For all tooth surfaces
- Mini model is excellent in narrow and deep pockets
Standard Gracey 13/14 Curette with ErgoSense® Handle (sharpen-free) 213-214SDES
- Area specific curette for the removal of deep subgingival calculus.
- For premolars’ and molars’ distal surfaces
Mini Gracey 13/14 Curette with ErgoSense® Handle (sharpen-free) 213-214MSDES
- Area specific curette for the removal of deep subgingival calculus
- For premolars’ and molars’ distal surfaces
Standard Gracey 11/12 Curette with ErgoSense® Handle (sharpen-free) 211-212SDES
- Area specific curettes for the removal of deep subgingival calculus
- For premolars’ and molars’ mesial surfaces
Mini Gracey 11/12 Curette with ErgoSense® Handle (sharpen-free) 211-212MSDES
- Area specific curette for the removal of deep subgingival calculus
- For premolars’ and molars’ mesial surfaces
Standard Gracey 9/10 Curette with ErgoSense® Handle (sharpen-free) 209-210SDES
- Area specific curettes for the removal of deep subgingival calculus
- For molars’ buccal and lingual surfaces using a horizontal technique
Standard Gracey 7/8 Curette with ErgoSense® Handle (sharpen-free) 207-208SDES
- Area specific curette for the removal of deep subgingival calculus
- For premolars and molars
- For buccal, mesial and lingual surfaces
Mini Gracey 7/8 with ErgoSense® Handle (sharpen-free) 207-208MSDES
- Area specific curette for the removal of deep subgingival calculus
- For premolars and molars
- For buccal, mesial and lingual surfaces
Standard Gracey 1/2 Curette with ErgoSense® Handle (sharpen-free) 201-202SDES
- Area specific curette for the removal of deep subgingival calculus
- For the finishing of subgingival root surface
- For incisors and premolars
Mini Gracey 1/2 Curette with ErgoSense® Handle (sharpen-free) 201-202MSDES
- Area specific curette for the removal of deep subgingival calculus
- For incisors and premolars
Sickle Scaler H6/H7 with ErgoSense® Handle (sharpen-free) 146-147SDES
- For the removal of supragingival calculus on all tooth surfaces
- Longer shank and smaller lateral bending than in LM-SharpJack™ (315-316SDES)
Sickle Scaler LM Nebraska with ErgoSense® Handle (sharpen-free) 128-128SDES
- Instrument for the anterior interproximals
LM-SharpJack™ Sickle Scaler with ErgoSense® Handle (sharpen-free) 315-316SDES
- Anterior/posterior scaler
- Extra long, thin dual-edged blades for easy and efficient interproximal access
Purchase with Confidence
For any direct Garrison purchase, Garrison offers a 30-day guarantee subject to the conditions on our returns web page. Learn More
Important Additional Cleaning Instructions
For most practices, having an instrument that never needs sharpening is by far worth being a bit more specific during the reprocessing cycle.
While LM DuraGradeMax instruments tolerate pretty much anything, LM Sharp Diamond instruments should be cared for little bit more carefully. To ensure the best performance and expected longevity, please follow these details (in conjunction with standard reprocessing steps):
- Avoid letting blood dry on the instrument tips. Human blood is corrosive.
- Avoid presoak and use of neutralizing / rinsing agents. Instead, gently clean and rinse the instruments with a non-metallic soft brush immediately after use.
- Do not leave the instruments wet or damp for any extended amount of time.
- All cleaning solutions should be neutral pH, always well below 10.
- Avoid strong and high-concentration citric acids.
- Do not use dishwasher salts when/if running Sharp Diamond instruments in dishwashers.
- Always check that instruments are fully dried in the sterilizer before storing them.